Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
2.
J Nucl Med Technol ; 52(1): 15-20, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443112

RESUMO

Chronic functional gallbladder disorder, characterized by biliary pain in the absence of structural pathology, poses a diagnostic challenge necessitating reliable cholecystagogues for accurate evaluation. However, recurrent shortages of synthetic cholecystokinin analogs have prompted the exploration of alternative agents. This paper describes the efficacy of Ensure Plus as a viable fatty meal substitute for hepatobiliary scintigraphy in assessing chronic functional gallbladder disorder. Through comparative studies, Ensure Plus demonstrates comparable diagnostic accuracy to cholecystokinin in similar patient populations. Furthermore, Ensure Plus demonstrates significant symptom improvement after cholecystectomy in patients with anomalous gallbladder ejection fractions. This paper offers a detailed protocol for the seamless integration of Ensure Plus into hepatobiliary scintigraphy, providing clinicians with a valuable tool to navigate cholecystokinin shortages while maintaining diagnostic precision in cases of chronic functional gallbladder disorder. The use of Ensure Plus not only addresses practical supply challenges but also underscores its potential as a cost-effective and clinically sound alternative in biliary diagnostics.


Assuntos
Doenças da Vesícula Biliar , Vitamina K , Humanos , Doenças da Vesícula Biliar/diagnóstico por imagem , Colecistocinina , Cintilografia
3.
J Nucl Med Technol ; 51(3): 167-175, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36195442

RESUMO

Dual-energy x-ray absorptiometry (DXA) is an accurate means to assess bone mineral density, determine the risk of a fragility fracture, and monitor response to therapy. Despite its seemingly straightforward nature-the review of 2-to-3 nondiagnostic images and a few automatically generated numbers-the proper performance and interpretation of DXA can often be complex. It is complex because it is highly dependent on many factors, such as image acquisition, processing, analysis, and subsequent examination interpretation. Each step is subject to potential errors, artifacts, and diagnostic pitfalls; hence, meticulous attention must be paid to the technique by both the technologist and the interpreting physician to provide high-quality results and, in turn, maximize the examination's clinical utility. This article is part 1 of a 2-part series. Part 1 will begin with a review of bone physiology and osteoporosis etiology, followed by a discussion of the principles underlying DXA and the technical procedure. Part 2 will focus on DXA interpretation and discuss scanning pitfalls and clues to recognizing issues and improving scan quality.


Assuntos
Densidade Óssea , Osteoporose , Humanos , Absorciometria de Fóton/métodos , Densidade Óssea/fisiologia , Osteoporose/diagnóstico , Artefatos
5.
J Nucl Med Technol ; 2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35610043

RESUMO

Diuretic renal scintigraphy plays a critical diagnostic role by providing a physiologic means for differentiating between obstructive and nonobstructive hydronephrosis as well as assessing the function of the affected kidney. The exam accuracy is highly dependent upon and benefits from close attention to the protocol. This article reviews kidney anatomy and physiology, patient preparation, available radiopharmaceuticals, diuretic administration, acquisition, processing, quantification, and interpretation criteria.

6.
J Nucl Med Technol ; 50(1): 73-74, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34872921

RESUMO

Abnormally increased 18F-FDG avidity of axillary lymph nodes has become a frequent diagnostic dilemma on PET/CT in the current climate of global vaccinations directed against severe acute respiratory syndrome coronavirus 2. This avidity is due to the inflammatory response evoked by vaccines and the nonspecific nature of 18F-FDG uptake, which is increased in both malignant and inflammatory processes. Similarly, 18F-fluciclovine, an amino acid analog indicated for the assessment of biochemical recurrence of prostate cancer, may also demonstrate nonspecific inflammatory uptake. We report a case of 18F-fluciclovine PET/CT obtained for concern about prostate cancer. In this case, isolated avid lymph nodes were seen in the left axilla. A screening questionnaire revealed that the patient had recently received the second dose of the Pfizer-BioNTech coronavirus disease 2019 vaccine in his left shoulder, and hence, the uptake was determined to be reactive.


Assuntos
COVID-19 , Neoplasias da Próstata , Axila/patologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , SARS-CoV-2 , Vacinação
7.
Clin Nucl Med ; 47(2): e161-e164, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34392283

RESUMO

ABSTRACT: A 71-year-old man with a history of carcinoid and prostate adenocarcinoma underwent 68Ga-DOTATATE PET/CT to evaluate new mediastinal lymphadenopathy. The scan revealed new carcinoid metastases, but the mediastinal nodes were not avid. 18F-FDG PET/CT was performed to evaluate for cardiac and mediastinal sarcoidosis, revealing a lack of cardiac sarcoidosis, but probable mediastinal sarcoidosis. 18F-Fluciclovine PET/CT was then performed for possible prostate metastases, revealing the patient's known prostate cancer. Three different PET radiopharmaceuticals revealed 3 different processes in a single patient within a 195-day period, demonstrating the power of nuclear medicine diagnostics.


Assuntos
Tumor Carcinoide , Neoplasias da Próstata , Idoso , Fluordesoxiglucose F18 , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Cintilografia
8.
J Am Coll Radiol ; 18(11): 1556-1563, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34371007

RESUMO

OBJECTIVE: The aim of this study was to assess variation in diuretic renal scintigraphy (DRS) practice patterns and quantify compliance with the national guidance in a large cohort of laboratories from different institutions and practice settings across the United States. METHODS: By means of an institutional review board-approved protocol, we extracted 107 facility-specific, adult DRS protocols and associated 174 reports from the Intersocietal Accreditation Commission database, representing all laboratories applying for genitourinary scintigraphy certification during the 2016 to 2018 accreditation cycle. From these, we assessed 40 variables regarding facilities and staffing, patient preparation, examination technique and acquisition, image processing, and reporting. RESULTS: Review of protocols and reports demonstrates a very high degree of variability in DRS practice across the United States and suboptimal compliance with societal guidelines and practice parameters. Some of the more variable or underreported parameters include the use of patient hydration, type and dosage of radiopharmaceutical, dosage and timing of diuretic administration, quantitative parameters assessed, and report content. CONCLUSION: There is high variability in the performance and reporting of DRS among laboratories applying for accreditation, similar to that seen in studies of other nuclear medicine examinations. The wide degree of practice variance may have a significant impact on diagnostic accuracy and patient management, with inaccurate or incomplete results. This survey impresses the need for standardization and improved quality of this important nuclear medicine examination.


Assuntos
Diuréticos , Medicina Nuclear , Acreditação , Adulto , Humanos , Cintilografia , Padrões de Referência , Estados Unidos
9.
J Nucl Med Technol ; 49(4): 354-355, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34330799

RESUMO

Recommended 177Lu-DOTATATE treatment regimens involve prophylaxis with antiemetics to counteract the emetogenic properties of the nephroprotective amino acid solution infusion. We describe a 58-y-old woman treated with 177Lu-DOTATATE for metastatic small-bowel carcinoid, who was allergic to many classes of antiemetics. Therefore, she was treated with 177Lu-DOTATATE without antiemetic prophylaxis. She tolerated the compounded amino acid infusion of lysine and arginine, followed by 177Lu-DOTATATE, without significant nausea or any vomiting. We hypothesize that aggressive antiemetic prophylaxis may not be necessary if a 177Lu-DOTATATE patient receives compounded lysine/arginine amino acid solutions. The omission would decrease overall health-care costs and limit possible medication side effects.


Assuntos
Antieméticos , Neoplasias Intestinais , Antieméticos/uso terapêutico , Feminino , Humanos , Náusea/tratamento farmacológico , Tomografia por Emissão de Pósitrons , Cintilografia , Vômito/tratamento farmacológico
10.
J Nucl Med Technol ; 49(3): 246-249, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33820862

RESUMO

The goal of this work was to determine U.S. diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for adult renal scintigraphy. Methods: Under an Institutional Review Board-approved protocol, data were collected from the Intersocietal Accreditation Commission during one 3-y accreditation cycle encompassing 110 facilities. Elements included radiopharmaceutical, administered activity, practice type, and examination volume. DRLs and AAAs were calculated and compared with non-U.S. values and societal recommendations as available. Results: Ninety-three facilities provided data on 99mTc-mercaptoacetyltriglycine (99mTc-MAG3), and 15 provided data on 99mTc-diethylenetriaminepentaacetic acid (99mTc-DTPA) for adult renal scintigraphy exams. Analysis demonstrated a DRL of 392.2 MBq (10.6 mCi) for 99mTc-MAG3 and 531.7 MBq (14.4 mCi) for 99mTc-DTPA, with an AAA of 370 MBq (10 mCi) for 99mTc-MAG3 and 445.9 MBq (12.1 mCi) for 99mTc-DTPA. Conclusion: The resultant calculated novel U.S. DRLs and AAAs may serve as benchmarks that nuclear medicine facilities may use to refine renal scintigraphy protocols, reduce patient doses, and potentially guide future societal guideline recommendations.


Assuntos
Níveis de Referência de Diagnóstico , Laboratórios , Acreditação , Adulto , Humanos , Cintilografia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Mertiatida , Pentetato de Tecnécio Tc 99m , Tomografia Computadorizada por Raios X
11.
J Nucl Med Technol ; 48(4): 336-339, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32709670

RESUMO

A pilot study was performed to determine whether the raw data from routinely obtained upright and supine myocardial perfusion scan (MPS) imaging could be used as an opportunity to screen for obstructive sleep apnea (OSA). We hypothesized that abnormal respiratory motion seen only on supine imaging (not upright imaging) corresponds with OSA. MPS supine-only respiratory motion was compared with known OSA diagnoses and with risk factors known to be associated with OSA. Methods: We reviewed 154 consecutive MPS studies from patients at our institution, including both exercise and chemical stress testing. All examinations were obtained because there was clinical suspicion of myocardial ischemia. We used the MPS panogram to assess for respiratory motion on supine stress or upright rest or stress imaging. We obtained the age, sex, body mass index, hypertensive history, and continuous positive airway pressure or OSA diagnosis history. Results: We compared the patients who had supine, stress-only respiratory motion with the remaining patients, assessing their OSA risk factors and known OSA diagnoses. In total, 65 patients (42.2%) had 3 or more OSA risk factors and 26 patients (16.9%) had a known OSA diagnosis. A similar percentage of patients with abnormal supine-only respiratory motion and patients with 3 or more OSA risk factors had a known OSA diagnosis, 9 (16.7%) and 14 (21.5%), respectively. Conclusion: We found a similar prevalence of known OSA diagnoses in patients with abnormal supine-only respiratory motion on MPS studies and patients with 3 or more OSA risk factors. The pilot study suggests that assessment of motion on MPS studies may provide an opportunity to also screen for OSA.


Assuntos
Programas de Rastreamento , Movimento , Imagem de Perfusão do Miocárdio , Respiração , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
12.
AJR Am J Roentgenol ; 215(2): 313-324, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32551905

RESUMO

OBJECTIVE. FDG PET/CT has emerged as an effective tool for the timely accurate assessment of how tumors respond to therapy. To standardize interpretation and reporting, numerous response criteria have been developed. This article will review the evolution of these criteria along with their strengths and weaknesses. CONCLUSION. Several qualitative assessments applicable to common malignancies have been developed in recent years that solve many of the challenges faced by their quantitative predecessors. These are reviewed, and information is provided regarding individual treatment efficacy and prognosis.


Assuntos
Fluordesoxiglucose F18 , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/terapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Linfoma/diagnóstico por imagem , Linfoma/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Resultado do Tratamento
13.
J Digit Imaging ; 33(3): 735-746, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31898039

RESUMO

Radiology by its nature is intricately connected to the Internet and is at the forefront of technology in medicine. The past few years have seen a dramatic rise in Internet-based technology in healthcare, with imaging as a core application. Numerous Internet-based applications and technologies have made forays into medicine, and for radiology it is more seamless than in other clinical specialties. Many applications in the practice of radiology are Internet based and more applications are being added every day. Introduction of mobile devices and their integration into imaging workflow has reinforced the role played by the Internet in radiology. Due to the rapid proliferation of wearable devices and smartphones, IoT-enabled technology is evolving healthcare from conventional hub-based systems to more personalized healthcare systems. This article briefly discusses how the IoT plays a useful role in daily imaging workflow and current and potential future applications, how mobile devices can be integrated into radiology workflows, and the impact of the IoT on resident and medical student education, research, and patient engagement in radiology.


Assuntos
Internet das Coisas , Radiologia , Dispositivos Eletrônicos Vestíveis , Computadores de Mão , Atenção à Saúde , Humanos , Internet
14.
Clin Nucl Med ; 45(1): 1-6, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31789906

RESUMO

OBJECTIVE: To determine if use of the oral cholecystagogue, Ensure Plus (EP), in hepatobiliary scintigraphy (HBS) leads to a similar distribution of normal and abnormal gallbladder ejection fractions (GBEFs) versus other historical secondary findings of chronic biliary disease in a similar patient population compared with the conventional cholecystokinin analog, sincalide. The HBS findings analyzed included the GBEF, small bowel transit time, gallbladder fill time, and reversal of the normal gallbladder versus small bowel transit. The secondary objectives were to determine whether patient outcomes were significantly different for EP and sincalide HBS study patients following cholecystectomy, namely, the surgical pathology and patient-reported biliary-type pain. METHODS: We reviewed all HBS examinations over a retrospective 34-month period. Data from 446 patients who underwent sincalide or EP HBS with GBEF determination for evaluation of chronic symptoms concerning for biliary etiology met the inclusion criteria. The aforementioned HBS findings and postsurgical patient outcomes were obtained for each patient group. RESULTS: Comparing HBS examinations performed with sincalide or EP, no significant differences were noted in the major HBS findings of similar patient populations. Outcomes for the sincalide and EP groups status post cholecystectomy were assessed to determine their sensitivity, specificity, positive predictive value, and negative predictive value. The outcomes assessed were the histopathology and patient-reported amelioration of biliary-type pain. No significant differences were noted. CONCLUSIONS: The sincalide and EP cholecystagogues did not lead to significantly different HBS findings for similar patient populations or postcholecystectomy outcomes.


Assuntos
Sistema Biliar/efeitos dos fármacos , Sistema Biliar/diagnóstico por imagem , Colecistectomia , Fígado/efeitos dos fármacos , Fígado/diagnóstico por imagem , Sincalida/farmacologia , Vitamina K/farmacologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Esvaziamento da Vesícula Biliar/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
16.
Am J Ophthalmol Case Rep ; 15: 100488, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31245653

RESUMO

PURPOSE: Describe a unique case of achiasma in a patient with Kapur-Toriello syndrome. OBSERVATIONS: We provide a brief review of achiasma with common findings on examination and imaging studies, and a published classification system. In addition, consistent with the rare Kapur-Toriello syndrome, he had a right unilateral cleft lip and palate, neurologic abnormality in his achiasma, anal atresia, vesicoureteral reflux, hypospadias, and growth deficiency. CONCLUSIONS: and Importance: Achiasma is an incredibly rare neurological deficit and we present the first case of achiasma in Kapur-Toriello syndrome.

17.
Radiographics ; 39(3): 822-841, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31059396

RESUMO

Fluorine 18 (18F) fluciclovine (anti-1-amino-3-18F-fluorocyclobutane-1-carboxylic acid [FACBC]) is a radiolabeled amino acid analog that takes advantage of the amino acid transport upregulation in several types of cancer cells. FACBC is taken up to a greater extent in prostate cancer cells than in surrounding normal tissue, providing an opportunity for its use in cases of this common cancer. In 2016, the U.S. Food and Drug Administration found the accuracy of FACBC PET to be superior to that of other molecular imaging techniques and subsequently granted approval for its use in PET of recurrent prostate cancer. As FACBC is an 18F radiotracer, an on-site cyclotron is not required for its production. This feature enables the widespread clinical availability of this agent and, in turn, an opportunity for improved patient care. The clinical pharmacology and imaging features of FACBC are reviewed, and the role of this agent in the imaging of recurrent prostate cancer, within the context of research that supports its effectiveness, is discussed. The administration of and image acquisition facilitated by using FACBC, as compared with 18F fluorodeoxyglucose, which is more widely used, are described. In addition, the criteria for interpreting FACBC imaging findings are outlined, with emphasis on common causes of false-positive and false-negative findings. ©RSNA, 2019.


Assuntos
Adenocarcinoma/secundário , Ácidos Carboxílicos , Ciclobutanos , Radioisótopos de Flúor , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Compostos Radiofarmacêuticos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/metabolismo , Adenocarcinoma/cirurgia , Idoso , Aminoácidos/metabolismo , Transporte Biológico , Ácidos Carboxílicos/farmacocinética , Ciclobutanos/farmacocinética , Diagnóstico Diferencial , Radioisótopos de Flúor/farmacocinética , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia/metabolismo , Estadiamento de Neoplasias/métodos , Especificidade de Órgãos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prostatectomia , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/cirurgia , Prostatite/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética
18.
AJR Am J Roentgenol ; 213(2): 243-253, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30995085

RESUMO

OBJECTIVE. The purpose of this article is to provide a review of 123I-ioflupane SPECT in the evaluation of suspected parkinsonian syndromes (PSs). This collection of diseases presents frequent diagnostic challenges, even by movement disorder and dementia specialists. CONCLUSION. The 123I-ioflupane scan serves as an imaging biomarker of the status of presynaptic dopamine transporters (DATs) in the striatum. As a result of neuronal death, DATs are greatly reduced in patients with PS neurodegenerative disorders, whereas clinical mimics generally do not show striatal DAT loss. This provides a tremendous opportunity for 123I-ioflupane to aid in the accurate and timely diagnosis of these patients and optimize their management.


Assuntos
Corpo Estriado/diagnóstico por imagem , Usos Diagnósticos de Compostos Químicos , Nortropanos , Transtornos Parkinsonianos/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Humanos , Radioisótopos do Iodo , Compostos Radiofarmacêuticos
19.
J Nucl Med Technol ; 47(1): 88-89, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30683689

RESUMO

A 48-y-old man with a history of colon cancer presented with recurrent hepatic metastasis along a prior microwave ablation bed. Split-bolus, intraprocedural 18F-FDG PET was performed to guide repeat microwave ablation and immediately confirm complete treatment. PET-guided ablation is highly accurate for targeting and treating malignant hepatic lesions and feasible for nonspecialized tertiary care hospitals without an onsite cyclotron.


Assuntos
Técnicas de Ablação , Fluordesoxiglucose F18 , Neoplasias Hepáticas/cirurgia , Micro-Ondas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doses de Radiação , Cirurgia Assistida por Computador , Neoplasias do Colo/patologia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Recidiva
20.
Clin Nucl Med ; 43(10): 721-727, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30153154

RESUMO

OBJECTIVE: To determine if classically reported findings associated with chronic cholecystitis on hepatobiliary scintigraphy (HBS), such as delayed small bowel (SB) transit, slow gallbladder (GB) filling, and reversal of the normal GB and SB transit, are associated with a depressed GB ejection fraction (GBEF). The secondary objectives were to determine whether GBEF is correlated with the time of GB filling, time of SB transit, or reversal of normal GB/SB filling sequence. We hypothesize that an association between a depressed GBEF and these classical HBS findings could validate them as surrogate markers for chronic GB disease. PATIENTS AND METHODS: We reviewed all HBS exams over a retrospective 16-month period. Data from 221 patients (mean age, 45.3 ± 15.2 years; 152 female and 69 male subjects) who underwent HBS with GBEF determination for evaluation of chronic symptoms concerning for biliary etiology met inclusion criteria. Classically reported findings for cholecystitis were recorded for each patient. Comparisons were made using t test and Fisher test analysis. RESULTS: Comparing exams with normal and abnormal GBEF values, there were no significant differences based on age, sex, GB fill time, normal versus delayed SB transit, and reversal of normal GB/SB filling sequence. Additionally, we did not see a correlation between the measured GBEF and GB fill time, SB transit time, or reversal of normal GB/SB filling sequence. CONCLUSIONS: Delayed SB transit, slow GB filling time, and reversal of the normal GB and SB filling sequence on HBS imaging are not associated with the measured GBEF and not predictive of chronic GB disease.


Assuntos
Sistema Biliar/diagnóstico por imagem , Doenças da Vesícula Biliar/diagnóstico por imagem , Doenças da Vesícula Biliar/fisiopatologia , Esvaziamento da Vesícula Biliar , Fígado/diagnóstico por imagem , Adulto , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS